FCC 80.859 Revised as of October 1, 2006
Goto Year:2005 |
2007
Sec. 80.859 Main power supply.
(a) The main power supply must simultaneously energize the radiotelephone
transmitter at its required antenna power and the required receivers. Under
this load condition the voltage of the main power supply at the
radiotelephone input terminals must not deviate from its rated potential by
more than 10 percent on ships completed on or after July 1, 1941, nor by
more than 15 percent on ships completed before that date.
(b) Means must be provided for charging any batteries used as a main power
supply. A continuous indication of the rate and polarity of the charging
current must be provided during charging of the batteries.