Sec. 80.1015 Power supply.
(a) There must be readily available for use under normal load conditions, a
power supply sufficient to simultaneously energize the bridge-to-bridge
transmitter at its required antenna power, and the bridge-to-bridge
receiver. Under this load condition the voltage of the power supply at the
power input terminals of the bridge-to-bridge radiotelephone installation
must not deviate from its rated voltage by more than 10 percent on vessels
completed on or after March 1, 1957, nor by more than 15 percent on vessels
completed before that date.
(b) When the power supply for a nonportable bridge-to-bridge radiotelephone
installation consists of or includes batteries, they must be installed as
high above the bilge as practicable, secured against shifting with motion of
the vessel, and accessible with not less than 26 cm (10 in.) head room.
(c) Means must be provided for adequately charging any rechargeable
batteries used in the vessel's bridge-to-bridge radiotelephone installation.
There must be provided a device which will give a continuous indication of
the charging current during charging.
[ 51 FR 31213 , Sept. 2, 1986, as amended at 58 FR 44954 , Aug. 25, 1993]
Goto Section: 80.1013 | 80.1017
Goto Year: 2005 |
2007
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public