Goto Section: 18.307 | 18.311 | Table of Contents
FCC 18.309
Revised as of October 1, 2006
Goto Year:2005 |
2007
Sec. 18.309 Frequency range of measurements.
(a) For field strength measurements:
-------------------------------------------------------------------------------
---------------------------------
Range of frequency
measurements
Frequency band in which device operates ---------------------------------------
---------------------------------
(MHz) Lowest frequency
Highest frequency
-------------------------------------------------------------------------------
---------------------------------
Below 1.705............................ Lowest frequency generated in the 3
0 MHz.
device, but not lower than 9 kHz.
1.705 to 30............................ Lowest frequency generated in the 4
00 MHz.
device, but not lower than 9 kHz.
30 to 500.............................. Lowest frequency generated in the T
enth harmonic or 1,000 MHz,
device or 25 MHz, whichever is
whichever is higher.
lower.
500 to 1,000........................... Lowest frequency generated in the T
enth harmonic.
device or 100 MHz, whichever is
lower.
Above 1,000............................ ......do........................... T
enth harmonic or highest
detectable emission.
-------------------------------------------------------------------------------
---------------------------------
(b) For conducted powerline measurements, the frequency range over which the
limits are specified will be scanned.
[ 50 FR 36070 , Sept. 5, 1985, as amended at 51 FR 17971 , May 16 1986]
Goto Section: 18.307 | 18.311
Goto Year: 2005 |
2007
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?
Thanks!
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public