Goto Section: 21.117 | 21.119
FCC 21.118
Revised as of January 7, 2005
Goto Year:2004 |
2006
Sec. 21.118 Transmitter construction and installation.
(a) The equipment at the operating and transmitting positions shall be
so installed and protected that it is not accessible to, or capable of
being operated by, persons other than those duly authorized by the
licensee.
(b) In any case where the maximum modulating frequency of a
transmitter is prescribed by the Commission, the transmitter shall be
equipped with a low-pass or band-pass modulation filter of suitable
performance characteristics. In those cases where a modulation limiter
is employed, the modulation filter shall be installed between the
transmitter stage in which limiting is effected and the modulated
stage of the transmitter.
(c) Each transmitter employed in these services shall be equipped with
an appropriately labeled pilot lamp or meter which will provide
continuous visual indication at the transmitter when its control
circuits have been placed in a condition to activate the transmitter.
Such requirement will not be applicable to MDS response stations or
MDS booster stations authorized pursuant to Sec. 21.913(e). In addition,
facilities shall be provided at each transmitter to permit the
transmitter to be turned on and off independently of any remote
control circuits associated therewith.
(d) [Reserved]
(e) At each transmitter control point the following facilities shall
be installed:
(1) A carrier operated device which will provide continuous visual
indication when the transmitter is radiating, or, in lieu thereof, a
pilot lamp or meter which will provide continuous visual indication
when the transmitter control circuits have been placed in a condition
to activate the transmitter.
(2) Facilities which will permit the operator to turn transmitter
carrier on and off at will.
(f) Transmitter control circuits from any control point shall be so
installed that grounding or shorting any line in the control circuit
will not cause the transmitter to radiate: Provided, however, That
this provision shall not be applicable to control circuits of stations
which normally operate with continuous radiation or to control
circuits which are under the effective operational control of
responsible operating personnel 24 hours per day.
[ 44 FR 60534 , Oct. 19, 1979, as amended at 52 FR 37783 , Oct. 9, 1987;
63 FR 65101 , Nov. 25, 1998]
Goto Section: 21.117 | 21.119
Goto Year: 2004 |
2006
CiteFind - See documents on FCC website that
cite this rule
Report errors in
this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please
help us improve these rules by clicking the Report FCC Rule Errors link to report an error.