Search for this:
 Search these answers
11 through 20 of 20 similar documents, best matches first.
<<previous   Page: 1 2   Results by:Thunderstone
11: Hallikainen Instruments Automatic Osmometer Model 1361
cavities separated by a semipermeable membrane. The bottom of the sample half-cell is formed by CI thin metal diaphragm which responds to changes of volume. Displacement ...
http://plaintext.hallikainen.org/org/hi/brochures/1361.pdf
37%****______
Size: 4.9M
Depth: 2
Find Similar
Match Info
Show Parents
12: Hallikainen Instruments Reflux End Point Analyzer Model 1353A
A piston type metering pump driven at a constant speed by an explosion-proof motor delivers a constant volume. A differential pressure controller is used to maintain ...
http://plaintext.hallikainen.org/org/hi/brochures/1353a.pdf
37%****______
Size: 2.8M
Depth: 2
Find Similar
Match Info
Show Parents
13: Hallikainen Instruments Continuous Viscometer
volume, is forced to flow at o constant rate through o capillary tube. The pressure drop across the capillary tube is converted to o pneumatic or electrical signal ...
http://plaintext.hallikainen.org/org/hi/brochures/1077.pdf
36%****______
Size: 5.0M
Depth: 2
Find Similar
Match Info
Show Parents
14: Halinco hi-Lights - Volume 2, Number 6 - July 27, 1962
attendant. A emall portion of the product to be analyzed is pumped into the Viscometer. The pump provides a constant low flow of 64 ml./min. or about 1 gallon of ...
http://plaintext.hallikainen.org/...hi/newsletter/620727.pdf
36%****______
Size: 376K
Depth: 2
Find Similar
Match Info
Show Parents
15: Hallikainen Instruments Distillation Analyzer Model 1463
at the stream temperature is removed by the coalescer from, the volume of sample required at the analyzer. Materials of Construction - All metal parts in contact ...
http://plaintext.hallikainen.org/org/hi/brochures/1463.pdf
36%****______
Size: 3.7M
Depth: 2
Find Similar
Match Info
Show Parents
16: Hallikainen Instruments - Analyzer Summary
fixed temperature, with a variable pump-out rate determined by changes in a sample evapora- tion characteristics. Fast response lends the analyzer to automatic control ...
http://plaintext.hallikainen.org/.../brochures/analyzers.pdf
36%****______
Size: 1.9M
Depth: 2
Find Similar
Match Info
Show Parents
17: Hallikainen Instruments Diacon Moisture Analyzer Model 1482
content of the stream (percent of saturation as established by cell temperature with liquid; by pressure and temperature with gas) decreases, the excess moisture ...
http://plaintext.hallikainen.org/org/hi/brochures/1482.pdf
36%****______
Size: 2.7M
Depth: 2
Find Similar
Match Info
Show Parents
18: Hallikainen hi-lights - Volume 10, Number 4 - July 1970
soon so that we can stock the literature rack in the shop. Eliminating the need for extra pump- ing from storage-tanks to blend-tanks by blending two streams in-line, ...
http://plaintext.hallikainen.org/...hi/newsletter/700700.pdf
35%****______
Size: 219K
Depth: 2
Find Similar
Match Info
Show Parents
19: Hallikainen Instruments Product Summary
the oil under test is placed in the cooling chamber of an electrothermal cooling unit. The detector assembly, consisting of two thermistors and a thermocouple, is ...
http://plaintext.hallikainen.org/...hi/brochures/summary.pdf
35%****______
Size: 2.0M
Depth: 2
Find Similar
Match Info
Show Parents
20: Hallikainen hi-lights - Volume 5, Number 7 - November-December ...
at the University of California hospital in San Francisco. WE'VE DONE IT! The first Bramson-Membrane- Heart-Lung Machine has been sold to the University of Cincinniti. ...
http://plaintext.hallikainen.org/...hi/newsletter/651112.pdf
34%***_______
Size: 2.6M
Depth: 2
Find Similar
Match Info
Show Parents
11 through 20 of 20 similar documents, best matches first.
<<previous   Page: 1 2  
Texis & Webinator Copyright (c) 2003 THUNDERSTONE - EPI, Inc.