1: | Hallikainen Instruments Distillation Analyzer Model 1463 cup which is vented to the atmosphere, allowing highly volatile components to escape. The remaining liquid is directed onto an evaporator tube. As the sample flows ... http://plaintext.hallikainen.org/org/hi/brochures/1463.pdf | 97% Size: 3.7M Depth: 2 Find Similar Match Info Show Parents |
2: | Hallikainen Instruments Boiling Point Analyzer - End Point Model ... filter element. The sample then passes into a water coalescer which removes all free water from the sample. Coalesced water is continually drained and returned to ... http://plaintext.hallikainen.org/org/hi/brochures/1238.pdf | 87% Size: 5.6M Depth: 2 Find Similar Match Info Show Parents |
3: | Hallikainen Instruments Boiling Point Analyzer Model 1340 heat input. Cooled distillate is removed from the boiler ot o constont rote equal to o percentage of the feed rate by o second metering pump. The amount removed con ... http://plaintext.hallikainen.org/org/hi/brochures/1340.pdf | 79% Size: 3.2M Depth: 2 Find Similar Match Info Show Parents |
4: | Hallikainen Instruments Boiling Point Analyzer Models 1007, 1347 ... onolyzer. The incoming sample is filtered by an IN-LINE FILTER containing on alundum element; the sample then posses into the COALESCER which removes all free water ... http://plaintext.hallikainen.org/org/hi/brochures/1007.pdf | 79% Size: 5.9M Depth: 2 Find Similar Match Info Show Parents |
5: | Hallikainen Instruments - Analyzer Summary anhydride plus many other materials where freezing point is a measure of purity. PROCESS CLOUD POINT ANALYZER Wax precipitation temperature is used as the principle ... http://plaintext.hallikainen.org/.../brochures/analyzers.pdf | 68% Size: 1.9M Depth: 2 Find Similar Match Info Show Parents |
6: | Hallikainen Instruments Process Cloud Point Analyzer Model 1466 the ASTM D97-IP 15 method. Detection is not affected by the water content or color of the sample. The analyzer has CI cloud point temperature range from -30-F to ... http://plaintext.hallikainen.org/org/hi/brochures/1466.pdf | 61% Size: 3.2M Depth: 2 Find Similar Match Info Show Parents |
7: | Hallikainen Instruments Reflux End Point Analyzer Model 1353A PROCESSES I m.aximum ambient to be expected, which incidentally, is also above the end point temperature of the sample. The THERMOTROL actuates six strip heaters ... http://plaintext.hallikainen.org/org/hi/brochures/1353a.pdf | 60% Size: 2.8M Depth: 2 Find Similar Match Info Show Parents |
8: | Hallikainen Instruments Freezing Point Analyzer Model 1470 increase in yield. A liquid sample is supercooled below its freezing point and then caused to partially fuse into a solid by mechanical impact. The exact freezing ... http://plaintext.hallikainen.org/...brochures/fpa100-468.pdf | 59% Size: 2.4M Depth: 2 Find Similar Match Info Show Parents |
9: | Hallikainen Instruments Filter-Coalescer Model 1363 saturated solution at the existing temperature. If this exit temperature is higher than ambient, any further cooling in the line connecting the FILTER-COALESCER with ... http://plaintext.hallikainen.org/org/hi/brochures/1363.pdf | 57% Size: 2.3M Depth: 2 Find Similar Match Info Show Parents |
10: | Hallikainen Instruments Laboratory Cloud Point Analyzer Model ... POINT ANALYZER is an automatic instrument for detecting and indicating the wax precipitation temperature, or cloud point of gas oils. The instrument is based on the ... http://plaintext.hallikainen.org/org/hi/brochures/1433.pdf | 50% Size: 4.1M Depth: 2 Find Similar Match Info Show Parents |
1 through 10 of 28 similar documents, best matches first. | ||